Overview
| MLIT filing number | 1134770 |
|---|---|
| Type | Statutory Recall (government-mandated recall) |
| Date filed | December 2, 2014 |
| Manufacturer(s) | Mitsubishi, UD Trucks |
| Production period | August 30, 2010 — March 31, 2014 |
| Vehicles affected | 1,540 units |
Defect
The heater hoses on large buses have insufficient strength, allowing internal reinforcement threads to break under water pressure. Continued use in this condition causes the hose to fail under water pressure, resulting in coolant leaking. This degrades defroster performance and may prevent the driver from maintaining adequate visibility through the windshield.
Corrective action
On all vehicles, replace the affected heater hoses with corrected parts, and replace the hose clamps from one-touch type clamps to wire-type clamps.
Affected models & chassis ranges
This filing lists 3 type code(s). A vehicle is affected if its chassis number falls within one of the ranges below.
| Type code (型式) | Model | Chassis ranges |
|---|---|---|
| LKG-AS96VP | スペースアロー A | AS96VP-20001 — AS96VP-20016; AS96VP-20005 — AS96VP-20017 |
| LKG-MS96VP | ふそうエアロエース | MS96VP-20012 — MS96VP-20571; MS96VP-20004 — MS96VP-20556 |
| QRG-MS96VP | ふそうエアロエース | MS96VP-20002 — MS96VP-70001; MS96VP-20586 — MS96VP-24137 |
Original Japanese (MLIT source text)
Show the original Japanese filing text
状況
大型バスのヒータホースの強度が不足しているため、水圧によりホース内部の補強糸が切れることがある。そのため、そのままの状態で使用を続けると、ヒータホースが水圧に耐えられず破損して冷却水が漏れ、デフロスタの機能が低下して前面ガラス直前の視野を確保できないおそれがある。
改善措置
全車両、強度が不足している箇所のヒータホースを対策品に交換し、ホースクランプをワンタッチ式クランプからワイヤ式クランプに交換する。
Source & verification
This entry reproduces public data from Japan's MLIT recall registry. English text is jdmvin.com's own translation; always verify against the official source:
https://renrakuda.mlit.go.jp/renrakuda/ris-detail-car.html?class=recalldatacar&id=3003416
Related
All Mitsubishi recalls · All UD Trucks recalls · All 2014 recalls · Recall Archive home