MLIT Statutory Recall · Japan

Isuzu MU, Wizard Recall 1211690 — Wiring

Filed October 14, 2004 · Isuzu

In October 2004, Isuzu filed a statutory recall with Japan's Ministry of Land, Infrastructure, Transport and Tourism (MLIT) concerning the Wiring, covering the MU, Wizard. The filing affects 1,232 vehicles manufactured between February 29, 2000 and December 26, 2001.

Overview

MLIT filing number1211690
TypeStatutory Recall (government-mandated recall)
Date filedOctober 14, 2004
Manufacturer(s)Isuzu
ComponentWiring
Production periodFebruary 29, 2000 — December 26, 2001
Vehicles affected1,232 units

Filing in context

The Wiring is the most frequently cited component category in this archive, appearing in 236 of its 4,890 filings. This filing is one of 40 Isuzu notifications from 2004 in this archive. For scale, 2,683 of the 4,890 filings in this archive report a larger number of affected vehicles; the vehicles involved here were manufactured over a span of about 1 year and 9 months.

Defect

The generator electrical wiring is routed with insufficient length. As a result, engine vibration applies excessive force to the wiring terminal, causing the terminal to fracture. This leads to a loss of charging function and, in the worst case, the engine may stall and be unable to restart. (Note: This notification supersedes the corrective action filed on September 18, 2001 under Notification No. Foreign-901. The prior corrective action was found to be insufficient; the scope of affected vehicles and the corrective measures have been revised accordingly.)

Corrective action

On all vehicles, install a corrected wiring harness supplementing the affected terminal section.

Affected models & chassis ranges

This filing lists 2 type code(s). A vehicle is affected if its chassis number falls within one of the ranges below.

Type code (型式)ModelChassis ranges
KH-UES73EW MU UES73EW-4111866 — UES73EW-4115460
KH-UES73FW WIZARD UES73FW-4111236 — UES73FW-4116438

Original Japanese (MLIT source text)

Show the original Japanese filing text

状況

 発電機の電気配線において、当該配線の長さ設定が不適切なため、配線の端子部にエン ジンの振動により過大な力がかかり、当該配線の端子部が折損するものがある。そのため 、充電ができなくなり、最悪の場合、原動機が停止し、再始動ができなくなるおそれがあ る。   (備考) 本届出は、平成13年9月18日「届出番号 外-901」の不具合に対する改善措置の内容が 不十分であったため、改善措置の内容及び対象車両の範囲を見直し、再度対策を行うもの である。

改善措置

全車両、当該端子部について対策用電気配線を追加する。

Source & verification

This entry reproduces public data from Japan's MLIT recall registry. English text is jdmvin.com's own translation; always verify against the official source:

https://renrakuda.mlit.go.jp/renrakuda/ris-detail-car.html?class=recalldatacar&id=3006102

Check your own vehicle: to see whether this filing affects a specific chassis number — and find every other recall for it — use the chassis lookup on the home page.

Related recalls

Same manufacturer, same component

Other Isuzu filings involving the Wiring, closest to this one by filing date.

Other recalls affecting the same models

Filings whose affected type codes overlap with this one, newest first.

All Isuzu recalls · All 2004 recalls · Recall Archive home