MLIT Statutory Recall · Japan

Recall 1144690 — Wiring

Filed April 11, 2019 · Subaru

Overview

MLIT filing number1144690
TypeStatutory Recall (government-mandated recall)
Date filedApril 11, 2019
Manufacturer(s)Subaru
ComponentWiring
Production periodNovember 30, 1998 — April 12, 2001
Vehicles affected33,181 units

Defect

The combination meter has an improperly designed circuit configuration. Prolonged exposure to moisture inside the cabin can cause condensation to form on the meter circuit board, leading to a short circuit in the power supply circuit. This may cause the circuit board to emit smoke and, in the worst case, result in a vehicle fire.

Corrective action

On all vehicles, clean the power supply circuit section of the combination meter circuit board and apply a moisture-resistant coating treatment.

Affected models & chassis ranges

This filing lists 2 type code(s). A vehicle is affected if its chassis number falls within one of the ranges below.

Type code (型式)ModelChassis ranges
GF-BE5 LEGACY BE5-002004 — BE5-081857
GF-BH5 LEGACY BH5-060011 — BH5-146025

Original Japanese (MLIT source text)

Show the original Japanese filing text

状況

コンビネーションメータにおいて、回路構成が不適切なため、車室内が長い間湿気にさらされると、メータ基板で結露が発生し、電源回路部がショートすることがある。そのため、メータ基板から発煙し、最悪の場合、火災に至るおそれがある。

改善措置

全車両、コンビネーションメータ基板の電源回路部を清掃し、防湿材コーティング処置を行う。

Source & verification

This entry reproduces public data from Japan's MLIT recall registry. English text is jdmvin.com's own translation; always verify against the official source:

https://renrakuda.mlit.go.jp/renrakuda/ris-detail-car.html?class=recalldatacar&id=3004491

Check your own vehicle: to see whether this filing affects a specific chassis number — and find every other recall for it — use the chassis lookup on the home page.

Related