MLIT Statutory Recall · Japan

Nissan Serena, Liberty and 4 more models Recall 1113462 — Exhaust Emission Reduction Device

Filed February 1, 2005 · Nissan

In February 2005, Nissan filed a statutory recall with Japan's Ministry of Land, Infrastructure, Transport and Tourism (MLIT) concerning the Exhaust Emission Reduction Device, covering the Serena, Liberty and 4 more models. The filing affects 151,168 vehicles manufactured between April 11, 2001 and May 20, 2004.

Overview

MLIT filing number1113462
TypeStatutory Recall (government-mandated recall)
Date filedFebruary 1, 2005
Manufacturer(s)Nissan
ComponentExhaust Emission Reduction Device
Production periodApril 11, 2001 — May 20, 2004
Vehicles affected151,168 units

Filing in context

The Exhaust Emission Reduction Device is the most frequently cited component category in this archive, appearing in 21 of its 4,890 filings. This filing is one of 38 Nissan notifications from 2005 in this archive. For scale, 330 of the 4,890 filings in this archive report a larger number of affected vehicles; the vehicles involved here were manufactured over a span of about 3 years and 1 month.

Defect

The heat shield on the exhaust manifold is improperly shaped, exposing the oxygen sensor mounting area of the front catalytic converter to repeated thermal stress. This causes the mounting area to corrode and detach, generating abnormal noise. Continued use after detachment may allow the oxygen sensor to separate entirely, significantly increasing exhaust noise.

Corrective action

On all vehicles, replace the exhaust manifold heat shield with the corrected part and inspect the condition of the oxygen sensor mounting area. If the mounting area has detached, replace the exhaust manifold-integrated front catalytic converter with the corrected part.

Affected models & chassis ranges

This filing lists 13 type code(s). A vehicle is affected if its chassis number falls within one of the ranges below.

Type code (型式)ModelChassis ranges
GH-TG10 BLUEBIRD SYLPHY TG10-105001 — TG10-105730
TA-JTNU30 BASSARA JTNU30-300101 — JTNU30-301167; JTNU30-301168 — JTNU30-301230
TA-JTU30 BASSARA JTU30-200101 — JTU30-204146; JTU30-204147 — JTU30-204490
TA-RM12 LIBERTY RM12-000001 — RM12-106973; RM12-013700 — RM12-106977
TA-RNM12 LIBERTY RNM12-000001 — RNM12-101001; RNM12-001986 — RNM12-101024
TA-TNU30 PRESAGE TNU30-100101 — TNU30-102690; TNU30-102691 — TNU30-102810
TA-TU30 PRESAGE TU30-000101 — TU30-008618; TU30-008619 — TU30-009047
TA-WRY11 WINGROAD WRY11-250012 — WRY11-300201; WRY11-300202 — WRY11-300878
UA-RC24 SERENA RC24-300001 — RC24-304192; RC24-304193 — RC24-304827
UA-RM12 LIBERTY RM12-000001 — RM12-106973; RM12-013700 — RM12-106977; RM12-106978 — RM12-114558; RM12-106979 — RM12-116435
UA-RNM12 LIBERTY RNM12-000001 — RNM12-101001; RNM12-001986 — RNM12-101024; RNM12-101059 — RNM12-101686; RNM12-101025 — RNM12-101973
UA-TC24 SERENA TC24-100001 — TC24-149950; TC24-149951 — TC24-155337
UA-TNC24 SERENA TNC24-200001 — TNC24-212444; TNC24-212445 — TNC24-215337

Original Japanese (MLIT source text)

Show the original Japanese filing text

状況

②エキゾーストマニホールドの遮熱板の形状が不適切なため、前側触媒の酸素センサ取り付け部が熱負荷を繰り返して受けて、当該取り付け部が腐食する。そのため、当該取り付け部がはがれて異音が発生し、そのまま使用を続けると、酸素センサが外れて、騒音が増大するおそれがある。

改善措置

②全車両、エキゾーストマニホールド遮熱板を対策品に交換すると共に、酸素センサ取り付け部の状態を点検し、当該取り付け部がはがれた場合は、エキゾーストマニホールド一体前側触媒を対策品と交換する。

Source & verification

This entry reproduces public data from Japan's MLIT recall registry. English text is jdmvin.com's own translation; always verify against the official source:

https://renrakuda.mlit.go.jp/renrakuda/ris-detail-car.html?class=recalldatacar&id=3009276

Check your own vehicle: to see whether this filing affects a specific chassis number — and find every other recall for it — use the chassis lookup on the home page.

Related recalls

Same manufacturer, same component

Other Nissan filings involving the Exhaust Emission Reduction Device, closest to this one by filing date.

Other recalls affecting the same models

Filings whose affected type codes overlap with this one, newest first.

All Nissan recalls · All 2005 recalls · Recall Archive home