MLIT Statutory Recall · Japan

Recall 1153690 — Electrical equipment / other

Filed August 24, 2023 · Toyota

Overview

MLIT filing number1153690
TypeStatutory Recall (government-mandated recall)
Date filedAugust 24, 2023
Manufacturer(s)Toyota
ComponentElectrical equipment / other
Production periodDecember 2019 — August 30, 2021
Vehicles affected7 units

Defect

The current rectification module within the DC-DC converter has an improper internal component design. Due to manufacturing variation, the module may fail in service and form a short circuit. This causes a warning light to illuminate while current continues to flow from the auxiliary battery, generating heat. In the worst case, this may result in a vehicle fire.

Corrective action

Replace the DC-DC converter on all vehicles with a corrected part.

Affected models & chassis ranges

This filing lists 2 type code(s). A vehicle is affected if its chassis number falls within one of the ranges below.

Type code (型式)ModelChassis ranges
2KG-XZB70改 COASTER XZB70-1005535 — XZB70-1006901
XZB70 COASTER XZB70-1005196

Original Japanese (MLIT source text)

Show the original Japanese filing text

状況

 電圧変換装置(DC-DCコンバータ)の電流整流モジュールにおいて、内部の部品構造が不適切なため、製造ばらつき等により使用過程で当該モジュールが故障した際、短絡回路が形成されることがある。そのため、警告灯が点灯するとともに補機バッテリから電流が流れ続けて発熱し、最悪の場合、火災に至るおそれがある。

改善措置

 全車両、DC-DCコンバータを対策品に交換する。

Source & verification

This entry reproduces public data from Japan's MLIT recall registry. English text is jdmvin.com's own translation; always verify against the official source:

https://renrakuda.mlit.go.jp/renrakuda/ris-detail-car.html?class=recalldatacar&id=3009437

Check your own vehicle: to see whether this filing affects a specific chassis number — and find every other recall for it — use the chassis lookup on the home page.

Related

All Toyota recalls · All 2023 recalls · Recall Archive home