MLIT Statutory Recall · Japan

Recall 1140590 — Body

Filed June 8, 2017 · Honda

Overview

MLIT filing number1140590
TypeStatutory Recall (government-mandated recall)
Date filedJune 8, 2017
Manufacturer(s)Honda
ComponentBody
Production periodDecember 2014 — May 2016
Vehicles affected27,372 units

Defect

On the gas-filled open stay of the tailgate, the paint applied to the outer tube's end cap is improper, allowing corrosion to develop due to salt exposure in coastal environments. Continued use allows the corrosion to progress, causing the outer tube to swell and the end cap to crack. When the tailgate is subsequently opened, the outer tube may break apart. In the worst case, bystanders in the vicinity may be injured.

Corrective action

On all vehicles, replace the gas-filled open stay assembly with the corrected/revised part.

Affected models & chassis ranges

This filing lists 2 type code(s). A vehicle is affected if its chassis number falls within one of the ranges below.

Type code (型式)ModelChassis ranges
DBA-JF1 N-BOX SLASH JF1-7000020 — JF1-7014316; JF1-7100003 — JF1-7101760; JF1-9000019 — JF1-9006328; JF1-9100003 — JF1-9100774
DBA-JF2 N-BOX SLASH JF2-7000006 — JF2-7002563; JF2-7100001 — JF2-7100256; JF2-9000013 — JF2-9001271; JF2-9100001 — JF2-9100164

Original Japanese (MLIT source text)

Show the original Japanese filing text

状況

 テールゲートのガス封入式オープンステーにおいて、外筒のエンドキャップ部の塗装が不適切なため、沿岸地域の塩分の影響で腐食することがある。そのため、そのままの状態で使用を続けると、腐食が進行し、外筒が膨らみエンドキャップが割れ、テールゲートを開く際に外筒が破損し、最悪の場合、周囲の人が負傷するおそれがある。

改善措置

 全車両、ガス封入式オープンステーアッセンブリを対策品と交換する。

Source & verification

This entry reproduces public data from Japan's MLIT recall registry. English text is jdmvin.com's own translation; always verify against the official source:

https://renrakuda.mlit.go.jp/renrakuda/ris-detail-car.html?class=recalldatacar&id=3004044

Check your own vehicle: to see whether this filing affects a specific chassis number — and find every other recall for it — use the chassis lookup on the home page.

Related