Overview
| MLIT filing number | 1115150 |
|---|---|
| Type | Statutory Recall (government-mandated recall) |
| Date filed | September 14, 2005 |
| Manufacturer(s) | Mitsubishi |
| Component | Wiring |
| Production period | July 25, 2003 — May 12, 2005 |
| Vehicles affected | 20,239 units |
Defect
The chassis electrical wiring routed beneath the cabin floor is improperly routed, causing it to contact the bracket that secures the engine harness on some vehicles. Continued use allows vibration from driving to short circuit the wiring and blow the fuse, or cause a disconnection. In the worst case, the speedometer may stop functioning, or the turn signals and hazard warning lights may fail to illuminate.
Corrective action
On all vehicles, inspect the clearance between the chassis electrical wiring and the bracket. If the clearance is below the specified value, adjust the clamp position to secure adequate clearance. If clearance adjustment is not possible, replace the wiring mounting bracket with the corrected part. If the wiring is damaged, perform the necessary repair.
Affected models & chassis ranges
This filing lists 32 type code(s). A vehicle is affected if its chassis number falls within one of the ranges below.
| Type code (型式) | Model | Chassis ranges |
|---|---|---|
| PA-FB70BB | FB70BB-510002 — FB70BB-511849 | |
| PA-FD70BB | FD70BB-510004 — FD70BB-510005 | |
| PA-FE70BB | FE70BB-510001 — FE70BB-511285 | |
| PA-FE70DB | FE70DB-510001 — FE70DB-514809 | |
| PA-FE71BB | FE71BB-510002 — FE71BB-511325 | |
| PA-FE71DB | FE71DB-510001 — FE71DB-514759 | |
| PA-FE72BB | FE72BB-510001 — FE72BB-510011 | |
| PA-FE72BE | FE72BE-510001 — FE72BE-510088 | |
| PA-FE72BEV | FE72BEV-510002 — FE72BEV-510017 | |
| PA-FE72DB | FE72DB-510001 — FE72DB-510281 | |
| PA-FE72DC | FE72DC-510001 — FE72DC-510397 | |
| PA-FE72DE | FE72DE-510001 — FE72DE-510728 | |
| PA-FE72DEV | FE72DEV-510004 — FE72DEV-511360 | |
| PA-FE73BB | FE73BB-510002 — FE73BB-510114 | |
| PA-FE73BEV | FE73BEV-510001 — FE73BEV-510004 | |
| PA-FE73DB | FE73DB-510002 — FE73DB-511584 | |
| PA-FE73DBX | FE73DBX-510001 — FE73DBX-510113 | |
| PA-FE73DBY | FE73DBY-510002 — FE73DBY-510027 | |
| PA-FE73DC | FE73DC-510001 — FE73DC-510359 | |
| PA-FE73DCX | FE73DCX-510001 — FE73DCX-510029 | |
| PA-FE73DCY | FE73DCY-510002 — FE73DCY-510019 | |
| PA-FE73DEN | FE73DEN-510002 — FE73DEN-510607 | |
| PA-FE73DEX | FE73DEX-510001 — FE73DEX-510049 | |
| PA-FE73DEY | FE73DEY-510001 — FE73DEY-510067 | |
| PA-FE78DEV | FE78DEV-510001 — FE78DEV-510017 | |
| PA-FG70DB | FG70DB-510001 — FG70DB-510339 | |
| PA-FG70DBD | FG70DB-510004 — FG70DB-510333 | |
| PA-FG72DB | FG72DB-510003 — FG72DB-510025 | |
| PA-FG72DC | FG72DC-510003 — FG72DC-510018 | |
| PA-FG72DE | FG72DE-510001 — FG72DE-510016 | |
| PA-FG73DC | FG73DC-510002 — FG73DC-510082 | |
| PA-FG73DE | FG73DE-510002 — FG73DE-510008 |
Original Japanese (MLIT source text)
Show the original Japanese filing text
状況
キャビン床下のシャシ用電気配線の取り回しが不適切なため、エンジンハーネスを固定する金具と当該配線が干渉するものがある。そのため、そのままの状態で使用を続けると、走行等の振動により当該配線がショートしてヒューズが切れる、又は断線して、最悪の場合、速度計が作動しなくなる、又は方向指示器及び非常点滅表示灯が点灯しなくなるおそれがある。
改善措置
全車両、シャシ用電気配線と金具の隙間を点検し、隙間が規定値以下の場合クランプ位置を調整し隙間を確保する。隙間調整が困難な場合は、当該配線の取付金具を対策品と交換する。 なお、当該配線が損傷している場合は、補修を実施する。
Source & verification
This entry reproduces public data from Japan's MLIT recall registry. English text is jdmvin.com's own translation; always verify against the official source:
https://renrakuda.mlit.go.jp/renrakuda/ris-detail-car.html?class=recalldatacar&id=3001207
Related