MLIT Statutory Recall · Japan

Recall 1146120 — Crankcase Ventilation System

Filed November 28, 2019 · Subaru

Overview

MLIT filing number1146120
TypeStatutory Recall (government-mandated recall)
Date filedNovember 28, 2019
Manufacturer(s)Subaru
ComponentCrankcase Ventilation System
Production periodJuly 2018 — October 22, 2018
Vehicles affected14,433 units

Defect

In the crankcase ventilation system, the PCV valve is made of an inappropriate material, resulting in insufficient durability at the crankcase connection. If the connection fails, engine oil enters the combustion chamber and burns, producing large amounts of white smoke from the muffler. In the worst case, the engine may stall while driving.

Corrective action

On all vehicles, replace the PCV valve with a corrected part.

Affected models & chassis ranges

This filing lists 3 type code(s). A vehicle is affected if its chassis number falls within one of the ranges below.

Type code (型式)ModelChassis ranges
5AA-GTE XV GTE-002017 — GTE-002741
5AA-SKE FORESTER SKE-002027 — SKE-006183
5BA-SK9 FORESTER SK9-002033 — SK9-012371

Original Japanese (MLIT source text)

Show the original Japanese filing text

状況

ブローバイガス還元装置において、PCVバルブの材質が不適切なため、クランクケース接続部の耐久性が不足しているものがある。そのため、当該接続部の破損により燃焼室にエンジンオイルが浸入し燃焼、マフラーから多量の白煙が発生して、最悪の場合、走行中にエンジンが停止するおそれがある。

改善措置

全車両、PCVバルブを対策品に交換する。

Source & verification

This entry reproduces public data from Japan's MLIT recall registry. English text is jdmvin.com's own translation; always verify against the official source:

https://renrakuda.mlit.go.jp/renrakuda/ris-detail-car.html?class=recalldatacar&id=3004633

Check your own vehicle: to see whether this filing affects a specific chassis number — and find every other recall for it — use the chassis lookup on the home page.