Recall 1109720 — Blowby Gas Recirculation System

Filed August 21, 2003 · Honda

Overview

MLIT filing number1109720
TypeStatutory Recall (government-mandated recall)
Date filedAugust 21, 2003
Manufacturer(s)Honda
ComponentBlowby Gas Recirculation System
Production periodOctober 2002 — May 2003
Vehicles affected29,494 units

Defect

The blowby gas recirculation system piping—specifically the breather tube length and breather pipe shape—is improperly designed. Repeated hard acceleration in low ambient temperatures may cause engine movement to dislodge the breather pipe. As a result, blowby gas may be released directly into the atmosphere during high engine load operation.

Corrective action

On all vehicles, replace the breather pipe and breather tube with the corrected parts.

Affected models & chassis ranges

This filing lists 7 type code(s). A vehicle is affected if its chassis number falls within one of the ranges below.

Type code (型式)ModelChassis ranges
LA-CL7 ACCORD CL7-1000013 — CL7-1002184
LA-CL8 ACCORD CL8-1000015 — CL8-1000997
LA-CL9 ACCORD CL9-1000035 — CL9-1006798
LA-CM2 ACCORD WAGON CM2-1000020 — CM2-1005009
LA-CM3 ACCORD WAGON CM3-1000024 — CM3-1001718
UA-CL7 ACCORD CL7-3000010 — CL7-3007774
UA-CM2 ACCORD WAGON CM2-3000010 — CM2-3005134

Original Japanese (MLIT source text)

Show the original Japanese filing text

状況

 ブローバイ・ガス還元装置の配管(ブリーザーチューブの長さ及びブリーザーパイプの 形状)が不適切なため、外気温度が低い状態での急加速等を繰り返し行うと、原動機の振 れによりブリーザーパイプが抜けるものがある。そのため、原動機の高負荷運転時にブロ ーバイ・ガスが大気中に放出されるおそれがある。

改善措置

全車両、ブリーザーパイプとブリーザーチューブを対策品と交換する。

Source & verification

This entry reproduces public data from Japan's MLIT recall registry. English text is jdmvin.com's own translation; always verify against the official source:

https://renrakuda.mlit.go.jp/renrakuda/ris-detail-car.html?class=recalldatacar&id=3000610

Check your own vehicle: to see whether this filing affects a specific chassis number — and find every other recall for it — use the chassis lookup on the home page.

Related

All Honda recalls · All 2003 recalls · Recall Archive home