Overview
| MLIT filing number | 1147810 |
|---|---|
| Type | Statutory Recall (government-mandated recall) |
| Date filed | July 20, 2020 |
| Manufacturer(s) | Nissan |
| Component | Fuel tank |
| Production period | December 22, 2018 — May 2020 |
| Vehicles affected | 13 units |
Defect
On some vehicles, the clearance between the fuel tank and the bolts securing the seat slide rail to the floor is insufficient, allowing those bolts to contact the top of the fuel tank. Continued contact may damage the fuel tank and cause a fuel leak.
Corrective action
On all vehicles, replace the seat slide rail mounting bolts with corrected parts. Additionally, inspect the fuel tank and, if damage is found, replace the fuel tank with a new unit.
Affected models & chassis ranges
This filing lists 1 type code(s). A vehicle is affected if its chassis number falls within one of the ranges below.
| Type code (型式) | Model | Chassis ranges |
|---|---|---|
| CBF-VNM20 | NV200バネット | VNM20-101475 — VNM20-107544 |
Original Japanese (MLIT source text)
Show the original Japanese filing text
状況
燃料タンクにおいて、シートスライドレールをフロアに固定するボルトとの隙間が小さいため、当該ボルトが燃料タンク上部に接触しているものがある。そのため、当該ボルトが燃料タンクを傷つけ、燃料が漏れるおそれがある。
改善措置
全車両、シートスライドレール固定ボルトを対策品に交換する。また、燃料タンクを点検し損傷がある場合は燃料タンクを新品に交換する。